Stove With Steel Tension, Tension Gauge And Tension Rollers

Jun 02, 2023

Stove with steel tension, tension gauge and tension rollers

Furnace tension

The strip passes through the furnace under controlled tension, intended to utilize the self-guidance of the steering roll. And avoid the deformation of the ladle due to excessive middle force (mainly in the heating section). The tension of each section is controlled separately by two tension measuring units at the inlet or outlet roller bearing bearing. The correction of the steel belt in the furnace is mainly realized by the comprehensive effect of roller type and tension.

The tension meter and control device can control the tension within the boundary range listed in the table below, that is, the control accuracy of better than 1% during stable operation or during the transition phase (limit acceleration of 3 mp m/sec (0.05 m / s2)).

The tension table (kN) is as follows:

tensiometer

section

tensiometer

tension

tension

tension

min.

Average

max.

kN

kN

kN

enter the mouth

 

2.16

6.00

23.38

preheating section

 

2.16

6.00

23.38

heating zone

T5

2.04

5.40

21.04

heating zone

T6

1.92

4.80

18.70

heating zone

T7

1.92

4.80

18.70

holding zone

T8

1.92

4.80

18.70

stretch roll

 

3.84

10.80

37.40

Fast cold section

T9

3.84

10.80

37.40

stretch roll

 

3.12

7.20

28.05

Over time period

T10-T12

3.12

7.20

28.05

The final cold section

T13

3.12

7.20

28.05

Tension Table (MPa)

section

tensiometer

tension

tension

tension

min.

Average

max.

MPa or N/mm2

MPa or N/mm2

MPa or N/mm2

enter the mouth

 

5

5

9

preheating section

 

5

5

9

heating zone

T5

4.5

4.5

8.5

heating zone

T6

4

4

8

heating zone

T7

4

4

8

holding zone

T8

4

4

8

stretch roll

 

8

8

16

Fast cold section

T9

8

8

16

stretch roll

 

6

6

13

Over time period

T10-T12

6

6

13

The final cold section

T13

6

6

13

news-624-382

Figure 3.24.38 Tension distribution diagram

Installation position table of the tension meter

tensiometer

control section

measuring range (N)

 

 

Minimum

Maximum

T5

heating zone I

1 800

25 000

T6

heating zone II

1 800

25 000

T7

heating zone III

1 800

25 000

T8

holding zone

1 800

25 000

T9

Fast cold section

3 000

40 000

T10

Over time period I

2 500

30 000

T11

Over the aging section II

2 500

30 000

T12

Over the aging section III

2 500

30 000

T13

The final cold section

2 500

30 000

 